Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Hefei WNK Smart Technology Co.,Ltd
Home ProductsSmart Pressure Transmitter

HART Protol Differential Smart Pressure Transducer For Flow Measurement

China Hefei WNK Smart Technology Co.,Ltd certification
China Hefei WNK Smart Technology Co.,Ltd certification
I'm Online Chat Now

HART Protol Differential Smart Pressure Transducer For Flow Measurement

HART Protol Differential Smart Pressure Transducer For Flow Measurement
HART Protol Differential Smart Pressure Transducer For Flow Measurement HART Protol Differential Smart Pressure Transducer For Flow Measurement HART Protol Differential Smart Pressure Transducer For Flow Measurement HART Protol Differential Smart Pressure Transducer For Flow Measurement

Large Image :  HART Protol Differential Smart Pressure Transducer For Flow Measurement

Product Details:
Place of Origin: China
Brand Name: WNK
Certification: ex-proof,CE,ISO
Model Number: WNK55
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Carton
Delivery Time: 3-30days
Payment Terms: D/A, T/T, Western Union
Supply Ability: 1000pcs per month
Detailed Product Description
Power Supply: 24VDC,12VDC 24VDC 12-36VDC Pressure Type: Absolute(A),Gauge(G),Differential
Output Signal: 0-5V/10V,4~20mA/HART Application: Oil,Liquid,gas,water,Water Utility System
Output: 2-wire 4-20mA,HART Communication Optional,4-20mA Hart Or Profibus Material: 316L,1Cr18Ni9Ti Stainless Steel
Process Connection: M20X1.5 Male,1/2NPT Etc,1/4NPT Or 1/2NPT,G1/4 Diaphragm Material: SS316L,Hastelloy C
Measurement Range: -0.1MPa~0; 0~100Mpa Housing Material: Aluminum Alloy,304 Stainless Steel
High Light:

smart type pressure transmitter

,

digital pressure transmitter

HART Protol Differential Smart Pressure Transducer For Flow Measurement

Product Description

Product Name

Smart High Precision Differential Pressure Transmitter

Applicable media

liquid, gas and steam

Pressure range

1-300Kpa~300bar,Negotiated

Accuracy

0.075%, higher on request

Stability

±0.15% of URL for 5 years

Temperature drift

±0.03% of URL/10ºC

Output signals

4~20mA, Hart, Profibus-PA for option, FF per request

Display

LCD, or pointer optional

Housing material

Aluminum14

Mechanical connection

M20×1.5;G1/2;1/2NPT

Protection class

IP66/67

Ex-proof

Exia II CT4, other option per request

Power Supply

10.5-55V DC 10.5-30V DC

Ambient temperature

-40 to 85ºC,-40 to 80ºCfor LCD header

Storage temperature

-45 to 85ºC,-40 to 80ºC for LCD header ;

Measurement

with display: 95*126*52 (mm)

without display: 95*115*52 (mm)

Net Weight

4kg (without bracket or process connection)

HART Protol Differential Smart Pressure Transducer For Flow Measurement 0

HART Protol Differential Smart Pressure Transducer For Flow Measurement 1

Differential Pressure Transmitter for Flow Measurement

By measuring the difference in fluid pressure while the fluid flows through a pipe,it is possible to calculate the flow rate. For differential pressure flow measurement,a primary and secondary element are used. The primary element is designed to produce a difference in pressure as the flow increases.The most common being the orifice plate,venturi,flow nozzle,and pitot tube. The secondary element is the differential pressure transmitter.It is designed to measure the differential pressure produced by the primary element as accurately as possible.In particular,it is important that the differential pressure measurement is not affected by changes in the fluid line pressure,temperature or other properties such as ambient temperature.

A good DP transmitter will ensure that the differential pressure is measured accurately,regardless of other changing parameters and will reliably transmit signal to represent the differential pressure. In a typical control loop,the transmitter signal is fed to the controller where output is used to regulate the flow rate through a control valve.

HART Protol Differential Smart Pressure Transducer For Flow Measurement 2

Details Images

HART Protol Differential Smart Pressure Transducer For Flow Measurement 3

HART Protol Differential Smart Pressure Transducer For Flow Measurement 4

HART Protol Differential Smart Pressure Transducer For Flow Measurement 5

The highest or middle part of the tank is the low pressure side [L] of the differential pressure transmitter, and the lowest part of the tank is the high pressure side [H];

Cable diameter φ8 ~ φ12.Signal terminals are located in a separate compartment of the electrical box. Unscrew the cover can be wiring.

Differential pressure transmitter housing material is aluminum 14, the process connection is stainless steel, with IP66 / 67 protection rating.

Product Usage

HART Protol Differential Smart Pressure Transducer For Flow Measurement 6

Product other application

  • Differential pressure transmitters are commonly used to calculate pressure, flow, liquid level, volume, etc. in media. It is mainly used in industrial control fields such as energy, chemical, natural gas, power plants, paper making For example, in a milk manufacturing industry, the proportion of pipelines needs to be controlled, and a hygienic differential pressure transmitter is used to monitor the flow of the pipeline and control the proportion.